Seismic Response of Slab Column Connection with Pyramid Shaped Drop Panel

, Ahmed Ibrahim, Dr. Hilal Abd Elkader, , Prof. Mohamed M. Husain, · International Journal of Engineering and Advanced Technology · 2022

Both experimental and finite element analysis (FEA) was used to study the seismic response of reinforced concrete (RC) interior slab-column connection made with pyramid-shaped drop panel subjected to vertical and horizontal loads. The dimensions of the models at “¼ ” linear scale for laboratory testing and FE Analysis (FEA) are derived from rules for dimensions of column drops, given a prototype “9.60m” grid and a slab thickness of “320mm”. Lab specimens were tested with the drops (flat slab, rectangular and pyramid-shaped) facing up, with loadings (vertical down and horizontal in grid direction) applied by jacks towards the top of a central projecting “150mm” square column. One flat slab (“80mm” thick no drop), tested to failure under vertical load (80kN), provided values for setting variables used in the FEA. The remaining 5 lab specimens (1 flat and 1 each rectangular and pyramid-shaped 40mm and 30mm drop thicknesses), under a fixed vertical load (40kN), were tested to failure by increasing a moment at the column slab junction applied by a horizontal load to the column “500mm” above the slab. FEA results for the same conditions compared closely with experimental results. The pyr