inklap

Numerical-field analysis of differential leakage reactance of stator winding in three-phase induction motors

V. I. Milykh · Electrical Engineering & Electromechanics · 2025

Introduction. The differential leakage reactance (DLR) of the stator winding of three-phase induction motors (TIM) is considered. It is known that DLR is the sum of the self-induction resistances of the winding from all harmonics of its magnetic field, excluding the first one, and its analytical definition is too complicated. But this reactance is a mandatory design element, including for calculating a number of other parameters and characteristics of such motors. Problem. Because of this, in the current classical design methods, the DLR are determined by a simplified formula with the addition of a number of coefficients, tabular and graphical dependencies. As a result, not only the physical and mathematical meaning of DLR is lost, but even the accuracy of its calculation is difficult to assess. Goal. The purpose of the paper consists in the comparative verification of the classical design calculation of the DLR of the TIM stator winding by numerical-field analysis of the harmonic composition of the EMF of self-inductions in this winding and by the determination of the considered DLR on such a basis. Methodology. Harmonic analysis is performed by obtaining the angular and time disc

📖 افتح في inklap 🔗 DOI 📮 اطلب بحثاً